Model |
INPCS-60K-N |
INPCS-150K-N |
INPCS-250K-N |
IN-PCS-375K-N |
IN-PCS-500K-N |
IN-PCS-630K-N |
|
AC side parameters |
|||||||
Rated output power (kW) |
60 |
125 |
250 |
375 |
500 |
630 |
|
Wiring mode |
Three-phase three-wire |
||||||
Output overload capacity (times) |
1.1 @ long term; 1.2 @ 5min; |
||||||
AC rated current (A) |
86A @ 45℃ |
180A @ 45℃ |
361A @ 45℃ |
541A @ 45℃ |
722A @ 45℃ |
909 @ 45℃ |
|
AC maximum current (A) |
103A @ 45℃ |
216A @ 45℃ |
433A @ 45℃ |
649A @ 45℃ |
866A @ 45℃ |
1090 @ 45℃ |
|
Allowable grid voltage (Vac) |
AC315 ~ 460 |
||||||
Allowable grid frequency (Hz) |
50/60(-2.5~1.5) |
||||||
Total current harmonic distortion rate |
≤ 3% (rated power) |
||||||
Rated power factor |
> 0.99 |
||||||
Output voltage distortion |
≤ 3% (linear rated power load) |
||||||
DC side parameters |
|||||||
Maximum DC power (kW) |
80 @ 45℃ |
160 @ 45℃ |
320 @ 45℃ |
320 @ 45℃ |
640 @ 45℃ |
756 @ 45℃ |
|
DC voltage range (Vdc) |
560~850 |
||||||
Maximum current (A) |
125 @ 45℃ |
250 @ 45℃ |
500 @ 45℃ |
853 @ 45℃ |
1008 @ 45℃ |
1008 @ 45℃ |
|
DC interface |
Model Suffix |
-N (optional 1, 2, 3, 4, 6, 8) |
|||||
Maximum number of routes |
1 |
2 |
4 |
6 |
8 |
||
Withstand short-circuit impulse current |
50kA @ 2ms |
||||||
Communication Interface |
|||||||
Communication Interface |
CAN2.0, RS485, and Ethernet |
||||||
Communication Protocol |
ModbusRTU, Modbus-TCP, CAN2.0 |
||||||
BMS Access |
Have (passive dry contact) |
||||||
Protection |
|||||||
AC and DC side lightning protection |
Have |
||||||
DC side insulation protection |
Have |
||||||
AC leakage current protection |
Have |
||||||
AC side protection |
Over-current, over-voltage, frequency |
||||||
DC side protection |
Over-current, over-voltage, short circuit, reverse polarity protection |
||||||
Over-temperature protection |
Have |
||||||
AC phase sequence adaptive |
Have |
||||||
IGBT protection |
Have |
||||||
Communication fault protection |
Have |
||||||
Cooling system fault protection |
Have |
||||||
Active Islanding Detection |
Have |
||||||
System parameters |
|||||||
System isolation |
Non-isolated |
||||||
Module topology |
Three-level interleaved parallel |
||||||
Operation mode |
PQ, VF, SVG, VSG |
||||||
Grid-connected and off-grid switching |
Optional |
||||||
EMI filtering on AC and DC sides |
Have |
||||||
System efficiency |
≥ 98% |
||||||
Charge-discharge conversion time (ms) |
≤ 50ms |
||||||
Weight (Kg) |
400 |
600 |
800 |
1000 |
|||
Dimensions (width × depth × height) mm |
1000×1000×2100 |
||||||
Noise (dB) |
<75 |
||||||
Protection level |
IP20 |
||||||
Allowable ambient temperature (℃) |
-20 ~ 50 |
||||||
Cooling mode |
Forced air cooling |
||||||
Permissible relative humidity |
0 ~ 95% (no condensation) |
||||||
Allowable Altitude |
No derating below 2000m; derating operation between 2000m and 4000m |
||||||
Note: This power level is standard configuration, special level can be customized |